Possible variations for the BeCode AIR / AIR+
Variation | for whom |
closures |
Fixed mode NFC | permanent users | up to 510 users |
Free mode NFC | variable users | 1 keycard can lock several locks |
Free mode advanced NFC | variable users | 1 keycard can lock only exactly one lock |
Colour signals
Programming: | Chronological order: | Signals: | |
Master Card | Mater Card | • • • • |
When the BeCode AIR / AIR+ is in manufacturing mode (i.e. after delivery), the first RFID card that is put in the front of it becomes the Master Card by default. This can‘t be decline by customer!
For additional deliveries first the existing mastercard must be supplied to the new BeCode AIR / AIR+, so that the "master key" function preserves.
Programming: | chronological order: | Signale: | |
Main-Admin | Main-Admin | • • • • • | |
Main-Admin | • • • • — | ||
Admin | Main-Admin | • • • • • | |
Admin | • • • • • | ||
Main-Admin | • • • • — | ||
Keycard | Admin | • • • • • | |
Keycard | • • • • • | ||
Admin | • • • • — | ||
Timeout | When no response in programming mode for approximately 10 sec. |
— |
Deprogramming: | Chronological order: | Signals: | |
Keycard | Admin | • • • • • | |
hold for about 10 seconds | Keycard | • • ... • • • • | |
Admin | • • • • — | ||
Admin | Main-Admin | • • • • • | |
hold for about 30 seconds | Admin | • • ... • • • • | |
Main-Admin | • • • • — |
Actions: | Signals: |
Lock in the open state: While supplying a Keycard. Lock closes. |
• • |
Lock in the closed state: While supplying the programmed Keycard. Lock opens. |
• • |
Lock in the closed state: While supplying a unknown Keycard. Lock doesn't open. |
• • |
While supplying the Master Card. Lock opens. | • • • • |
Actions: |
Signals: |
|
While supplying a programmed Keycard. Lock open. | • | |
While supplying a unknown Keycard. Lock doesn't open. | • | |
While supplying a Main-Admin or Admin card. Programm mode will be started. Lock doesn't open. |
• • • • • |
Error messages / Status messages: | Signals: | Cause: |
While supplying a programmed Keycard. Lock opens. | • | Lock opens |
While supplying a programmed Keycard. Lock doesn't open. | • • • • • | Low battery |
continuous red light at the lock | —————— | Hardware fault |
Red blinking after opening | • 5s • • | Battery warning |
After inserting a new battery. Ready for use | • • • • • | System reboots |
Programming: Programming cards in Free Mode
1. Hold the Master Card in front of the BeCode AIR / AIR+ for two to three seconds. The BeCode AIR / AIR+ displays a green blinking light. When the card is removed, it blinks red.
2. Please wait 30 seconds.
For additional deliveries first the existing Master Card must be supplied to the new BeCode AIR / AIR+, so that the "master key" function preserves.
Programming RFID cards in Fixed Mode
1. Hold the Main-Admin Card in front of the BeCode AIR / AIR+ for two to three seconds. The BeCode AIR / AIR+ displays a green blinking light. When the card is removed, it blinks red.
2. Please wait 30 seconds
1. Hold the Main-Admin Card in front of the BeCode AIR / AIR+ for two to three seconds. The BeCode AIR / AIR+ displays a green blinking light. When the card is removed, it blinks red.
2. Then hold the Admin Card to be programmed in front of the BeCode AIR / AIR+ for two to three seconds. The BeCode AIR / AIR+ blinks green briefly and then red again.
3. Repeat this procedure for all Admin Cards that you’d like to program (max. 5 pcs).
4. After that, hold the Main-Admin Card once again in front of the BeCode AIR / AIR+ for two to three seconds in order to finalize the procedure.
The BeCode AIR / AIR+ displays a green blinking light. When the card is removed, it blinks red.
1. Hold an Admin Card in front of the BeCode AIR / AIR+ for two or three seconds. The BeCode AIR / AIR+ first displays a blinking green light. When the card is removed, it blinks red.
2. Then hold the keycard to be programmed in front of the BeCode AIR / AIR+ for two to three seconds. The BeCode AIR / AIR+ first displays a green blinking light. When the card is removed, it blinks red.
3. Repeat this procedure for all keycards that you’d like to program (max. 62 pcs).
4. After that, hold the Admin Card once again in front of the BeCode AIR / AIR+ for two to three seconds in order to finalize the procedure. The BeCode AIR / AIR+ first displays a green blinking light. When the card is removed, it blinks red.
Deprogramming RFID cards in Fixed Mode
The Main-Admin Card cannot be deprogrammed by the customer. If the Main-Admin Card is lost, the BeCode AIR / AIR+ has to be sent back to the manufacturer for reactivation.
1. Hold the Main-Admin Card in front of the BeCode for about 2-3 seconds.
The BeCode AIR / AIR+ first displays a green blinking light. When the card is removed, it blinks red.
2. After that, the Admin Card to be deprogrammed is held for approximately 30 seconds in front of the BeCode AIR / AIR+ until it blinks red once.
3. Along with the Admin Card, all keycards that were programmed with this Admin Card will be deprogrammed automatically. Keycards that were programmed by other Admin Cards will remain valid.
4. Repeat this procedure with all Admin Cards that you would like to deprogram.
5. After that, hold the Main-Admin Card once again in front of the BeCode AIR / AIR+ for two to three seconds in order to finalize the procedure.
The BeCode AIR / AIR+ displays a green blinking light. When the card is removed, it blinks red.
1. Hold the Admin Card that was used to program the keycard to be deprogrammed in front of the BeCode for about 2-3 seconds. The BeCode AIR / AIR+ first displays a green blinking light. When the card is removed, it blinks red.
2. After that, the Keycard to be deprogrammed is held for approximately 15 seconds in front of the BeCode AIR / AIR+ until it blinks red once.
3. Repeat this procedure with all Keycards that you would like to deprogram.
4. After that, hold the Admin Card once again in front of the BeCode AIR / AIR+ for two to three seconds in order to finalize the procedure.
1. To deprogram all Keycards, hold the Admin card that was used to program the keycards in front of the BeCode for about 15 seconds until it blinks red once.
2. All Keycards that were programmed with this Admin card will be deprogrammed at the same time.
If several Admin cards are used, this procedure will have to be carried out separately for each Admin card.
The Admin card remains valid.
Instructions
The optimum operating temperature for the BeCode AIR / AIR+ is temperature range between 14º C and 24º C.
The first supplied card to the lock will be programmed in Fixed Mode as Main-Admin Card and in Free Mode as Master Card!
When the BeCode AIR / AIR+ is unlocked with a keycard, the crown has to be turned within approximately four seconds in order to open the lock. After that amount of time has ex¬pired, the BeCode AIR / AIR+ will be relocked automatically.
When the BeCode AIR / AIR+ is unlocked with a keycard and the lock is opened by turning the crown, the cabinet door can be opened and closed as often as desired without the BeCode AIR / AIR+ automatically locking it again. The BeCode AIR / AIR+ will only be relocked when the crown is turned back to the original position.
The programming or deprogramming mode is terminated when no action is carried out (i.e. the card is neither introduced nor removed) for approximately 10 seconds. The BeCode AIR / AIR+ blinks red once.
Brand-new RFID cards should not be stored near the BeCode AIR / AIR+ in order to avoid any unintentional programming.
The cards themselves may be stored together. They will not influence each other.
The Main-Admin card should definitely be stored in a safe location, such as in a safe.
In Fixed Mode there are Main-Admin Cards, Admin Cards and Keycards.
In Free Mode there are one Master Card ("master key function") and Keycards.
A maximum of 62 keycards can be programmed per BeCode AIR / AIR+ classic - maximum 510 BeCode AIR / AIR+ NFC.
Error analysis
Check the washer. Is it in the right position (Installation instructions).
- Check if the keycard is recognized
- Change the battery of the BeCode
Please change the battery typ CR 2477 - video tutorial.
The AIR / AIR+ is ready after 10 sec. until it blinks green 5x.